Technicial Specifications
Minimum Rating | 219 ekW 219 ekW |
Maximum Rating | 940 ekW 940 ekW |
Frequency | 60hz 60hz |
Configuration | Vee-12, 4-stroke-Cycle-Diesel Vee-12, 4-stroke-Cycle-Diesel |
Aspiration | Turbocharged-aftercooled aspiration Turbocharged-aftercooled aspiration |
Bore | 5.71 in 145 mm |
Stroke | 6.38 in 162 mm |
Displacement | 1959 in³ 32.1 l |
Emissions | IMO III emissions certified (SCR required) IMO III emissions certified (SCR required) |
Rated Engine Speed | 1500 rpm 1500 rpm |
Governor | Electronic (A5 ECM) Electronic (A5 ECM) |
Refill Capacity | Lube Oil System w/ oil filter change: 146 L (38.5 gal) Lube Oil System w/ oil filter change: 146 L (38.5 gal) |
Oil Change Interval | 750 hrs 750 hrs |
Cooling | Heat exchanger, keel or radiator cooled Heat exchanger, keel or radiator cooled |
Generator | SR5 - Form Wound SR5 - Form Wound |
Length | 167.2 in/4245 mm (minimum), 226.1 in/5742 mm (maximum) 167.2 in/4245 mm (minimum), 226.1 in/5742 mm (maximum) |
Width | 59.9 in/1521 mm (minimum), 89.8 in/2280 mm (maximum) 59.9 in/1521 mm (minimum), 89.8 in/2280 mm (maximum) |
Height | 70.4 in/1747 mm (minimum), 92.8 in/2356 mm (maximum) 70.4 in/1747 mm (minimum), 92.8 in/2356 mm (maximum) |
Package Dry Weight | 15721 lb/7131 kg (minimum), 21998 lb/9978 kg (maximum) 15721 lb/7131 kg (minimum), 21998 lb/9978 kg (maximum) |
Advantages and Features
Emissions
Utilizes SCR Technology to enable IMO III emission regulations compliance while lowering operational costsControl Strategy
Utilizes closed loop air assisted DEF dosing control strategy that delivers: Highest efficiency mixing and control to lower operational costs; Extends emissions useful life; Ensures compliance; Flexible to urea qualityFuel System
Enhanced control of fuel injection optimized through crank timing and the A5 ECM technologyPower Reserve
Industry leading power reserveCertifications
Wide range of available Marine Society certificationsWarranty
Industry-leading warranty coverage for factory packaged componentsService
Global dealer network for service in any locationStandard Equipment
-
AIR INLET SYSTEM
- Separate circuit aftercooled (SCAC)
- Closed crankcase fumes disposal
-
CONTROL SYSTEM
- 24V control system
-
COOLING SYSTEM
- Heat exchanger or Keel Cooling
- Watercooled exhaust manifold and turbocharger
- Hard seawater lines – no flexible hoses
- Flanges for cooling connections, ANSI or DIN
-
FUEL SYSTEM
- Primary fuel filter with water separator installed on base frame
- Duplex fuel filters with hybrid fuel lines
-
GENERATORS AND GENERATOR ATTACHMENTS
- IP23, air cooled, form wound SR5 generator offered in 380, 400, 415 and 690 V
-
LUBE SYSTEM
- Oil fill, simplex filter and dipstick
-
MOUNTING SYSTEM
- Helical spring/rubber isolated mounting for vibration and structure borne noise reduction
-
GENERAL
- Right or left hand service sides
- Customer wiring and service tool connector
Optional Equipment
-
ALARM AND PROTECTION
- MGCPIIIB control panel with Cat® Alarm and Protection System
- IP44 generator protection
-
EXHAUST SYSTEM
- Muffler
- Water-in-fuel and exhaust temperature sensors
- SOLAS approved spray shielding
-
CHARGING SYSTEM
- Charging alternator
-
FUEL SYSTEM
- Manual or electric fuel priming pump
- Fuel cooler
-
LUBE SYSTEM
- Duplex oil filters
-
STARTING SYSTEM
- Starting motors – air, electric or redundant