Technicial Specifications
Continuous Rating | 400 ekW @1.0pf 400 ekW @1.0pf |
Fuel Type | Natural Gas, Biogas, Coal Gas, Hydrogen Blend (up to 25%) Natural Gas, Biogas, Coal Gas, Hydrogen Blend (up to 25%) |
Maximum Electrical Efficiency | 43.1% / 42.1% 43.1% / 42.1% |
Frequency | 50 / 60 Hz 50 / 60 Hz |
RPM | 1500 or 1800 rpm 1500 or 1800 rpm |
Engine Model | CG132-8 CG132-8 |
Displacement | 1067.9 in³ 17.5 l |
Aspiration | TA TA |
Bore | 5.2 in 132 mm |
Stroke | 6.3 in 160 mm |
Length | 122 in 3100 mm |
Width | 70 in 1780 mm |
Height | 85 in 2150 mm |
Dry Weight - Genset | 12610 lb 5720 kg |
Advantages and Features
High Efficiency, Lower Operating Costs
- Highest efficiency in its output class
- Up to 42.5% improved electrical efficiency
- Reduced vibration and stress on components
Low installation, Building and Operating Costs
- Compact design with integrated fuel tanks for daily refilling
- Lower setup costs than comparable engines
- Reduced investment costs through expanses product scope and TPEM digital control system
- Long maintenance intervals (up to 80,000 hours)
- Optimized oil management
Optimized Lubrication Consumption
- Consumes less than 0.1g/kW of oil
- Up to 66% lower lubricant consumption than comparable models
- Longer lubricant change (up to 4,000 hours) and oil change intervals
Standard Equipment
-
Air Inlet
- One-element single-stage air cleaner with enclosure and sevice indicator
- Turbocharger with a water-cooled bearing case for all cylinder
-
Control Panels
- TPEM (Total Plant & Energy Management System)
-
Cooling
- flange connections for JW inlet and outlet
- Electrical jacket water and aftercooler coolant pump
- Jacket water and SCAC thermostats
- ANSI/DN customer flange connections for JW inlet and outlet
-
Exhaust
- Exhaust waste gate for the CG132B-16
- Closed crankcase ventilation system
- PEARL/Low resistence exhaust system
-
Fuel system
- Independently controlled cylinder monitoring and ignition system
- Electronic fuel metering valve
- Pre-chamber spark plugs
-
Generator
- Anti-condensation space heater
- Reactive droop
- closed-coupled generator result in no torque transmission to the base frame
- Winding temperature detectors
- Busbar connections
- 3-phase sensing and KVAR/PF control
- grid code generator
-
Starting/Charging
- 24V starting motors
- Battery disconnect switch
-
General
- Crankshaft vibration damper and guard
Optional Equipment
-
Cooling
- CHP skid
-
Grid Code Compliance
- 50Hz: Germany, Belgium, Great Britain, Italy, Poland, and Netherlands